Steamflow Direct - email newsletter Site Updates

Spirax & Forbes Marshall

Ball Float Steam Traps


 

Ball Float Steam Trap FT-20
The FT-20 Ball Float Steam Trap is a condensate drain trap of cast steel body, cover and stainless steel internals.


CA-10
CA-10 is a condensate drain trap of cast iron body and cover for compressed air and other pressurized gases. The trap body is equalised with the pressure in the system through the balancing connection on top of the trap body.
For more information, download a Technical Information Sheet from the sidebar on the right.


CA-20
CA-20 is a condensate drain trap of cast steel body and cover for compressed air and other pressurized gases. The trap body is equalised with the pressure in the system through the balancing connection on top of the trap body.
For more information, download a Technical Information Sheet from the sidebar on the right.




An indirect steam heating application needs trapping with suitable type and size of trap. In case of all process equipment, a Ball Float Steam Trap should be selected. A trouble free operation of steam trap is of biggest importance for efficient process. Thus, preventive maintance of steam trap is necessary. This is achieved by installing a Strainer before trap and monitoring the performance of steam trap online using a Sensor chamber and monitoring System . When trap is discharging into closed loop condensate circuit, it is necessary to avoid any back flow and back pressure on the trap to ensure high capacity and effective operation. A Disc Check Valve plays important role in steam trapping in closed loop condensate circuit. Thus Spirax Marshall Steam Trap Module is designed to offer complete steam trapping, monitoring and maintenance solution. For customized sizing and selection, please refer to FT 10, FT 14 and FT 20 Technical Information Sheets. The Ball Float Trap Module is supplied as a flange to flange connection. Monitor to be bought separately.

Jet dyeing is done to relieve dimensional stress as well as to achieve good dye penetration. Approximate steam load in the heat exchanger is 300 kg/hr. The temperature of liquor is to be maintained at 130 to 140 oC by using dry saturated steam at pressure of 4 bar (g).

To ensure that there is no water/condensate logging in the steam space of the heat exchanger, immediate removal through Ball Float Steam Trap Module is necessary